PostYou are now at: Home » Supply » machinery/equipments »

160℃/180℃ HIGH TEMPERATURE WATER MTC

Click image to view original image
Brand: Hengju
Price: Negotiable
Min.Order: 1 Set
Supply 30 Set
Delivery: Shipment within days since the date of payment
Address: Chinaland
Valid until: Never Expire
Updated on: 2019-06-06 21:24
Hits: 1875
Enquiry
Company Detail
You are not logged in. Please log in to view contact details
After registering for free as a member, you can...
Supply and demand information Promote their products
The establishment of corporate shops Do business online
Not a member, Register Now
 
 
Details
HIGH TEMPERATURE WATER MTC 2
(Magnetic-driven pump with high-temperature).


FETURE:
1.Adopted microcomputer controller,easy to operate.P.I.D. multi-stage temperature control system can maintains an accuracy of ±0.1℃.
2.Adopted with high efficiency water cycle pump, suitable for precise mouds and the temperature requirement for mold loop with minor diameter, can achieve precise temperature controller and high efficient heat exchange.
3.Multiple safety devices including high-pressure protection,overheat protection,inlet water pressure deficit protection,safety pressure relieving,automatic water supplying,air exhausting and automatic shutdown cooling protection function.
4.Main pipes are made of uni-body 304 stainless steel.
5.Temperature control range within 180℃(Optional for magnetic pump).
6.Adopts indirect cooling method,which makes temperature controller more precise and realizes fast heat exchange.
7.Adopts magnetic pump with stable performance and no leakage
8.Water manifolds and Teflon hose as optional.
9. Sufficient safety protection and visible alarm,easy for maintenance.
10. Isolated box type electric control provides long life time service.
SPECIFICATIONS
Model Unit HJW-160506 HJW-161009 HJW-161012 HJW-181006 HJW-181509 HJW-181512
Temp.Control Range 160℃ 180℃
Temp.Control Accuracy P.I.D ±0.1℃
Power Supply AC3φ 380V/50HZ
Heat Transfer Medium Water
6.Adopts indirect cooling method,which makes temperature controller more precise and realizes fast heat exchange. Indirect Cooling
Heating Power KW 6 9 12 6 9 12
Pump Power KW 0.37 0.75 0.75 0.75 1.1 1.1
Max.Pump Flow L/min 42 135 135 135 60 60
Max.Pump Pressure KG/cm2 2 2.5 2.5 3 5 5
alert Function Phase-Missing/Water Insufficient/Over-Heat/Over Current
Circulating Water Pipe mm 12 12 12 12 12 12
Circulating Water Pipe inch (2x2) 3/8 (4x4) 3/8 (4x4) 3/8 (2x2) 3/8 (4x4) 3/8 (4x4) 3/8
Dimension(LxWxH) mm 790*400*760 790*400*760 790*400*760 790*400*760 790*400*760 790*400*760
Approx.Net Weight KG 76 80 80 76 83 83
In order to ensure the stability of heating temperature, the pressure for cooled water must be within 2-5 bar.
The testing condition for pumping parameter: 50HZ power supply, 20T purified water (the deviation between the max.pressure and max.flux allows ±10% tolerance.)
The voltage specification for machine is: 3400VAC, 50Hz

Total: 0 [Show All]  Related Reviews
 
More »Our Others Products

[ SupplySearch ]  [ Add To Favourite ]  [ Tell Friends ]  [ Print Content ]  [ Violation Report ]  [ Close Window ]